Owner’s Manual Model 44459File: AJ570/41383 book p. 1-19/art Created: 9-28-98 dbFolder: AJ570/Hunter/41383 Alt: 2-2-99 dbPrints blackSINCE
PAGE 1010-11INSTALLATIONThis thermostat includes two #8 slotted screws and two wallanchors for mounting. To install your thermostat, you should haveth
PAGE 11 Each wire coming from the wall to the existing thermostat isconnected to a terminal point on that thermostat. Each of theseterminal points is
PAGE 12 Remove the wallplate from your thermostat by pressing therelease tab on the bottom of the thermostat. (See Figure 2.) Position wallplate on wa
PAGE 13 Match and connect the labeled wires to the appropriatecoded terminal screws on the mounting plate. (SeeFigure 4, 5.) Ignore any wires which m
In order for this Hunter thermostat to control your system, thesystem type must be specified by selector switches on the printedcircuit board inside t
PAGE 15Switch SettingSwitch Function Alternate StandardSW 5 F° / C° Celsius FahrenheitSW 6 12 Hr. / 24 Hr. 24 Hour 12 HourSW 7 Span +2°F / –1°F +1°F /
PAGE 1616-17PROGRAMMINGRemove the mylar label covering the LCD display window before operating thermostat.Setting Time and DayHOURMINDAYRETURNEXAMPLE:
PAGE 17Studies conducted by the Department of Energy estimate thatsetting your thermostat back 10°F (6°C) for two 8-hour periodsduring winter can redu
PAGE 1818-19PROGRAMMINGPersonal Program ScheduleDay Program 1 Program 2 Program 3 Program 4Mon. Time Time Time Time- Fri. Temp Temp Temp TempSat. Time
Your thermostat can be programmed for weekdays and forSaturday and Sunday. Use the Programming steps below toenter or revise programs to match your
Ask Your Local Retailer forOther Quality Products from HunterTo locate your nearest Hunter Dealer, call 1-800-4HUNTER,or visit The Hunter Fan Co. webs
20-21PROGRAMMINGWeekday Programming (cont.)Step 3Step 5 If you desire only weekday programs, press to return to normal mode. After 15 seconds, the
Step 2 Press to enter program mode, display shows weekday programs. Press to reach the Saturday programs.PROGStep 3PROGDAYStep 5 Press to change to
You may want to review the programs to confirm that the settings are compatible with your lifestyle.22-23PROGRAMMINGReviewing ProgramsWeekdayPrograms
Current time and temperature. Thermostat is set to AUTO, and the heating system is on. Press for 1 second or less. Set Temperature is shown abov
The System Selector switch on the front of the thermostat determines the operating mode of the thermostat.You may select COOL, OFF, HEAT, AUTO. In ord
To end the Temporary Manual Override:NOTE: The Auto Season Changeover feature will not operate while the thermostat is in Temporary ManualOverride. Re
When the System Selector is in AUTO position, the thermostatwill automatically change between Heating and Cooling systems,depending on your program. W
Press to exit Home Today mode before the schedule ending time.“HOME” is no longer displayed on the LCD screen, and thethermostat returns to the curr
72.7I.70.28-29OPERATIONEnergy MonitorENERGYENERGY Press and hold for 3 seconds to reset the Energy Monitor’s counters.The display will blink, and all
Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s performance and energyefficiency, ch
IntroductionModel Information:Model Number ____________________________________Serial Number _____________________________________Date Purchased______
72.7I.70.30-31OPERATIONAuto RecoveryHunter’s Auto Recovery feature meets the ENERGYSTAR®guidelinesfor energy efficiency by allowing the heating or coo
Backlighting (INDIGLO®night-light) Press the Light Bar on the left side of the thermostat to illuminate thedisplay. The display will remain illumina
When the batteries become too weak for normal operation, thethermostat enters the second stage low battery warning whichshuts down the thermostat. In
If the thermostat is unable to control your system due to anunexpected battery problem, the thermostat will enter ErrorMode. In this condition, the th
34-35TROUBLESHOOTINGProblem SolutionSCRAMBLED OR DOUBLE DISPLAY(numbers over numbers)NO DISPLAYENTIRE DISPLAY DIMSPROGRAM DOES NOT CHANGE AT YOUR DESI
Solution (cont.)ERRATIC DISPLAYIF UNIT CONTINUES TO OPERATE IN THE OFF POSITIONTHERMOSTAT PERMANENTLY READS “HI,” “LO,” OR “ERR-” AFTER PRESSING RESET
36-37WIRING DIAGRAMS5-wire Heat/Cool SystemX - No ConnectionTHERMOSTATGWYRHRCHeat Relayor ValveHeat24V SupplyFanRelayCoolContactorCool24V SupplyTHERMO
Single-stage Heat PumpTHERMOSTATGWYO/BRHRCHeat Pump24V SupplyFanRelayCompressorContactorReversingValveJumperX - No ConnectionO/B2-wire Heat OnlyTHERMO
3-wire Cool Only3-wire Heat OnlyTHERMOSTATWRHRCHeat Relayor ValveHeat24V SupplyFanRelayTHERMOSTATGWYRHRCCoolContactorFanRelayCool24V SupplyG YO/BO/B38
B99A p30-40 2/7/03 9:59 AM Page 10
Table of ContentsRead This Before Installing Thermostat 6Features 8What You Need 10Remove Old Thermostat 10Wire Labeling 11Mount Wallplate and Thermos
© 2003 Hunter Fan Company 41610-01 2/03Hunter Fan Company2500 FRISCO AVENUEMEMPHIS, TN 38114®B99A p30-40 2/7/03 9:59 AM Page 11
OPERATIONS (continued)SAFETY FEATURESTROUBLESHOOTINGWIRING DIAGRAMSTemporary Manual Override 24Permanent Manual (Vacation) Override 25Auto Season Chan
IMPORTANT1Read the entire installation section of this Owner’sManual thoroughly before you begin to install oroperate your Hunter Thermostat.REMOVE TH
PAGE 7Read This Before Installing Thermostat (continued)POWER FAILURE7Whenever the main power is interrupted or fails, thebattery power retains the pr
PAGE 8FeaturesHOME TODAY: Overrides energy-saving program temperatures whileyou are at home for the day.ENERGY: Measures anddisplays heating and cooli
PAGE 9Provides permanenttemperature setting byoverriding storedprograms. It also returnsthe thermostat to currentprogram control frommanual override o